日本老化Jaica-Test kit for Potential Anti Oxidant (PAO)


Home > Products > Test kit for Potential Anti Oxidant (PAO) Rev.080604
Test kit for Potential Anti Oxidant (PAO) Test kit for Potential Anti Oxidant (PAO)
Test kit for Potential Anti Oxidant (PAO)
Suitable for detection of total antioxidant capacity in serum and food extracts. For research use only.
Antioxidant assay:
Test kit for Potential Anti Oxidant (PAO) Oxidative stress plays on important role in various diseases and aging. The control of oxidative stress is expected to be useful to prevent diseases and aging.Oxidative stress is caused by the imbalance between reactive oxygen species (ROS) and antioxidant defense system. For accurate assessment of oxidative stress, measurement of ROS, oxidative damage and antioxidant activity may be essential. Recently, antioxidants as functional foods which scavenge ROS attract a great deal of attention.
Principle of this assay:
Test kit for Potential Anti Oxidant (PAO) In the PAO assay kit, an easy and convenient method to measure antioxidant capacity is provided. Utilizing the reduction of cupric ion (Cu++ to Cu+), antioxidant capacity of samples can be detected in 5 minutes. Samples are mixed with Cu++ Solution. Cu++ are reduced by antioxidants to form Cu+. Reduced Cu+ react with Chromatic Solution (Bathocuproine) , and can be detected by absorbance at wavelength 480 to 490 nm. Antioxidant capacity can be calculated from the Cu+ formed. PAO can detect not only hydrophilic antioxidants such as Vitamin C, glutathione, but also can detect hydrophobic antioxidants such as Vitamin E. Applicable for assessment of total antioxidants of serum, foods and beverage samples.
Test kit for Potential Anti Oxidant (PAO)
Specifications:
Method: Colormetric assay(detection: 480 – 492 nm)
Assay range: 21.9 – 4378 µmol/L (cupric ion reducing power)
Format: 96 wells
Storage: Room temperature (10 – 25°C)
Applications: Human and animal serum samples, foods and beverage samples.
Required but not provided: A micro plate reader (measuring wavelength 492 nm)
Pipettes and pipette chips
Plastic test tubes
Distilled water
NaOH, HCl solution and pH meter (Not required if standards are prepared with distilled water only).
Test kit for Potential Anti Oxidant (PAO)
Content of this kit:
Standard (Uric acid powder): 1 vial Test kit for Potential Anti Oxidant (PAO)
Sample diluent: 1 bottle
Cu++ solution: 1 bottle
Stop solution: 1 bottle
Micro titer plate: 1 plate (96 wells)
Test kit for Potential Anti Oxidant (PAO)
Assay procedure:
1) Prepare 6 levels of standards by diluting 2mM uric acid.
2) Please prepare plastic test tubes for 6 levels of standards and each sample. Pour 390 µL of Sample Diluent, and add 10 µL of standards or diluted samples.
3) Pour 200 µL of mixture to Micro titer plate. Use 200 µL of Sample Diluent for blank well.
4) Read absorbance at 490 nm (as READ1).
5) Add 50 µL of Cu++solution to each well, mix gently, and incubate at room temperature for 3 minutes.
6) Add 50 µL of Stop solution, mix gently, and read absorbance at 490 nm (as READ2).
7) Please draw standard curves by plotting the difference of absorbance readings (READ2 – READ1) as vertical axis, and concentration of uric acid standards (mM) as horizontal axis. Calculate the corresponding uric acid concentration of samples. Multiply corresponding uric acid concentration (mM) of samples by 2189, to estimate antioxidant power (µmol/L).
1mM of uric acid = 2189 µmol/L (copper reducing power)
Test kit for Potential Anti Oxidant (PAO)
References
1) Oxidative imbalance and cathepsin D changes as peripheral blood biomarkers of Alzheimer disease: A pilot study
E Strafacea, P Matarresea, L Gambardella, R Vona, A Sgadari,MC Silveri, W Malorni
FEBS Letters 579, p2759-766 (2005)
2) Oxidative stress and its association with coronary artery disease and different atherogenic risk factors
C. VASSALLE, L. PETROZZI , N. BOTTO, M. G. ANDREASSI and G. C. ZUCCHELLI
Journal of Internal Medicine 256, p308-315(2004)
3) Antioxidant capacity as a reliable marker of stress in dairy calves transported by road
P Pregel, E Bollo, FT Cannizzo, B Biolatti, E Contato, and PG Biolatti
Veterinary Record 156, p53-54 (2005)
4) Vitamin E-coated dialyzers reduce oxidative stress related proteins and markers in hemodialysis ? a molecular biological approach.
LA Calo, A Naso, E Pagnin, PA Davis, M Castoro, R Corradin, P Riegler, C Cascone, W Huber and A Piccoli
Clinical Nephrology, Vol.62(5), p355-361 (2004)
5) Oxidative stress-related factors in Bartter’s and Gitelman9s syndrome: relevance for angiotensin IIsignalling.
Calo LA, Pagnin E, Davis PA, Sartori M, Semplicini A.
Nephrol Dial Transplant 18(8) p1518-1525 (2003)
6) Effect of epoetin on HO-1 mRNA level and plasma antioxidants in hemodialysis patients.
Calo LA, Stanic L, Davis PA, Pagnin E, Munaretto G, Fusaro M, Landini S, Semplicini A, Piccoli A.
Int. J Clin. Ther 41(5), p187-192 (2003)
7) Restored Antioxidant Capacity Parallels the Immunologic and Virologic Improvement in Children with Perinatal Human Immunodeficiency Virus Infection Receiving Highly Active Antiretroviral Therapy.
M Martino, F Chiarelli, M Moriondo, M Torello, C Azzari, and L Galli
Clinical Immunology 100(1),p82-86 (2001)
Test kit for Potential Anti Oxidant (PAO)
 
Product name Code Assay range Assay time Format
Test kit for Potential Anti Oxidant (PAO) KPA-050 21.9-4378 µmol/L 5 minutes 96 wells

Related patent: US PAT.6613577, JP PAT.5917951. Made in Japan.

Test kit for Potential Anti Oxidant (PAO)

If you are in the U.S., please click here
to Genox Corporation (Los Angeles, CA)
.

Instruction manual Technical information
Test kit for Potential Anti Oxidant (PAO)
[NOTICE]: Our products are for RESEARCH USE ONLY. Not for diagnostic, medical or other use.

We are making efforts to prevent errors or mistakes on preparing web site documents, instruction manuals and products.
But even if some damage would causedby such faults, we will be exempt from responsibility.

Page top

日本衰老控制研究所 Japan Institute For the Control of Aging (JaICA) 专注于衰老研究领域。提供DNA氧化损伤检测试剂盒,并且处于该领域的领先地位。JaICA氧化应激相关产品:DNA氧化损伤检测、脂质氧化检测、蛋白氧化检测、抗氧化分析,以及微量元素分析。详情请咨询JaICA中国区代理商:上海金畔生物科技有限公司。